Package Types
XH1 Series:
XH3 Series: |
All SOIC devices 150-mil (narrow body)
All SOIC devices 300-mil
(wide body)
|
Index Time:
|
1.1 sec (without test time) |
System Throughput: |
Up to 2500 units per hour, typically without test time |
Temperature Range: |
-40 °C to +150 °C |
Contacting: |
One test site Kelvin contact, typically 90 mR (mΩ) |
Pitch: |
1.27 mm and 0.8 mm available |
Input / Output Characteristics
Several Sections
Available |
Input: |
Tube holder for manual loading or automatic tube loader |
Handler(s): |
One, two or three in cascade depending on users request |
Output: |
Tube holder for manual unloading or good devices automatic tube
unloader. Two
output categories. |
Jam Rate: |
1 jam per 2000 devices typically, but depending on the quality
of the package |
Physical Characteristics |
Dimensions: |
Approx. 800(w) x 1500(d) x 1800(h) mm
(for a single handler without tube loader and unloader) |
Weight: |
Approx. 130 kg for a single handler, without test system |
Power
Requirements
|
Electrical: |
220 V, 50 Hz, 1.5 kW, 110 V possible |
Air: |
Dried air at 10 bar max. The handler runs typically at 6 bar |
LN2 Requirements: |
7.5 kg/h LN2 at -40 °C with a max pressure of 1.6 bar |
Temperature Characteristics
-40 °C to +150 °C (±3 °C) for a tri-temp
660mm soak length for a 150-mil handler.
960mm soak length for a 300-mil handler.
Machine Interface
RS 232, one character protocol:
R = Retest, F = Fail, G = Good device, sent by test system.
S = Start test, sent by handler.
Logic Control System
A PC, equipped with the XPEQT high-speed
serial card controls the handlers’ state machine, error
trapping and diagnostics.
Temperature
Control System
An intelligent temperature PID control algorithm,
controlled
by the PC assures the set point. This system is watchdog
protected, and uses a weighed function of air and metal temperature
to
control the temperature in the test and soak chambers. |