XHPS is a gravity fed, wide temperature range (-20 °C
- +85 °C)
handler, designed to test 300-mil SO-8 pressure devices from 0bar to
1 bar.
Devices are loaded into the input track of the handler from tubes
placed manually one by one in the input tube holder. One tube contains
64 devices. In the input track devices are soaked to the necessary
temperature.
At the end of the input track devices are singulated and slide down
to the test position, where they are fixed by stopper pins. At this
position an electrical contact with the device is made and test air
pressure is applied. Devices are also tested for leakage.
After testing, devices are sorted in 2 categories, pass and fail.
A bad device is rejected to the fail position, a good device continues
the flow towards a tube.
The computer constantly monitors the handler's operation by the use
of optical sensors placed along the path. If a jam would occur, the
program will display the appropriate error message.
The Graphical User Interface provides an easy way of setting up the
parameters of the handler operations and allows diagnostic control
over all actuators and sensors of the handler.
The software logs lot information and errors to a data base.