Home
 
 

XHAC Specifications

Package Types:

DIL14 and DIL16 packages 300 mil wide, plastic and ceramic.
Devices are packaged in tubes. When switching from one package type to another, a number of settings on the handler have to be adjusted by the operator, mainly mechanical ones.

Cycle time:

Cycle time Cy of the accelerator handler is calculated as follows:
Cy = tt +5, where Cy > 10 sec. "tt" is the testtime. In each Cy, four (4) devices are handled, making the machine in average delivering a device every Cy/4 sec.

Throughput:

An average of maximum 1440 devices tested per hour when input and output module are filled and emptied on time and the device testtime is less than 5 sec (See previous paragraph).

Physical Characteristics

Handler Dimensions:

Approx. 3000(w) x 2000(d) x 2100 (h) mm

Electrical Cabinet Dimensions:

Approx. 950(w) x 600(d) x 2000 (h) mm

Handler Weight:

600 kg

Power Requirements

Electrical:

AC 380V, 50 Hz, 4 kW

Air:

Oil-free dry air, 6 to 10 bar

Environment Specifications

Temperature:

Ambient (20..30°C), non-condensing

Noise Level:

<75 dBA in operating condition

Note: this is the noise level of the handler only! The shaker produces a considerably higher noise level, depending on the way of testing (continuous or pulsed). It is probably advisable to locate the entire handler with shaker in a separate sound-isolated room.